3BA4: Creating/Loading a Cell
Creating a new Cell
- Select either File -> Cell -> Create from the main menu,
or "Create" in the "Cell" section of the "Session" palette.
- Under "Cell Name" enter the desired name.
The "Navigator" button can be used to ensure you are at the right location.
- Under "Process" enter the pathname of the Process, or use the "Navigator" button to locate it
(current location: /users/Public/BAICT/3BA4/3BA4-CMOS ).
- Under "Design Rules" enter the location of the design rules file you intend to use.
(current rules file:
/users/Public/BAICT/3BA4/3BA4-rules.txt)
- Leave "Attach Library" blank.
- Under "Angle Mode" use Ninety or Forty-Five, as required
- Under "Cell Type" use Block
- Ensure Connectivity is set to "No connectivity"
- Click on "Ok" or type RETURN.
Loading an existing Cell
- Select either File -> Cell -> Open from the main menu,
or "Open" in the "Cell" section of the "Session" palette.
- Enter the Cell Name in the space provided, or use the "Navigator" button
to find your Cell.
- Under "Access", ensure that "Edit" is chosen, and not "Read Only".
- Click on "Ok" or type RETURN.
Closing a Cell (without exiting IC Station)
Simplest way: Double-click on top-left corner of Cell window.